AFTER HEAT SENSORS AND PAPER ARE PLACED IN THE SAFE, THE UNIT IS LOCKED AND EXPOSED TO A UNIFORMLY DISTRIBUTED FIRE. THE FURNACE IS REGULATED TO REACH A MAXIMUM TEMPERATURE OF 1700°F OR FOR A PERIOD OF ONE HOUR, OR 1850°F FOR TWO HOURS, THEN ALLOWED TO COOL WITHOUT OPENING THE FURNACE. THE INTERIOR TEMPERATURE IS RECORDED THROUGHOUT THE TEST AND DURING THE COOLING PERIOD UNTIL A DEFINITE DROP IS SHOWN AND MUST NEVER EXCEED 350°F.
ONCE COOLED, THE UNIT IS OPENED AND EXAMINED FOR USABILITY. THE UNITS LOCKING MECHANISMS AND PARTS FASTENINGS ARE EXAMINED FOR SECURITY AND THE INTERIOR EXAMINED FOR VISIBLE EVIDENCE OF UNDUE HEAT TRANSMISSION.
EXPLOSION HAZARD TESTTHE SAFE IS LOCKED AND PLACED INTO A FURNACE PREHEATED TO 2000°F. THIS TEMPERATURE IS MAINTAINED FOR 30 MINUTES (2 HOUR TEST IS 45 MINUTES) AND IF NO EXPLOSION RESULTS, THE UNIT IS ALLOWED TO COOL WITHOUT OPENING THE FURNACE DOORS.
ONCE COOLED, THE UNIT IS OPENED AND EXAMINED FOR USABILITY. THE UNITS LOCKING MECHANISMS AND PARTS FASTENINGS ARE EXAMINED FOR SECURITY AND THE INTERIOR EXAMINED FOR VISIBLE EVIDENCE OF UNDUE HEAT TRANSMISSION.
FIRE IMPACT TEST (MANUFACTURER'S OPTION)AFTER THE EXPLOSION HAZARD TEST THE SAFE IS REMOVED FROM THE FURNACE AND WITHIN TWO MINUTES IS DROPPED 30' ONTO A RIPRAP OF BRICK ON A HEAVY CONCRETE BASE. AFTER IMPACT THE UNIT IS EXAMINED FOR DEFORMATION, RUPTURE OF PARTS, DAMAGED INSULATION AND ANY OTHER OPENINGS INTO THE INTERIOR OF THE UNIT.
ONCE COOLED THE UNIT IS INVERTED AND REHEATED TO 1550°F FOR A PERIOD OF 30 MIN. (2 HOUR TEST 45 MIN. AT 1638°F).
ONCE COOLED, THE UNIT IS OPENED AND EXAMINED FOR USABILITY. THE UNITS LOCKING MECHANISMS AND PARTS FASTENINGS ARE EXAMINED FOR SECURITY AND THE INTERIOR EXAMINED FOR VISIBLE EVIDENCE OF UNDUE HEAT TRANSMISSION.